Search
Translate:
About Us
Products
Components
Adapters
Amplifiers
Attenuators - Continuously Variable
Attenuators - Fixed
Attenuators - PIN Diode
Attenuators - Step
Bias Tees
Couplers - Directional
Couplers - Hybrid
DC Blocks
Detectors
Fiber Optic Products
Limiters - PIN Diode
Mixers
Modulators
Multipliers
Oscillators
Phase Shifters
Power Dividers
Switches - PIN Diode
Synthesizers
Terminations
Integrated Microwave Assemblies (IMA)
Amplifier Assemblies
Converter Assemblies
Converter Modules
SATCOM Terrestrial Equipment
Frequency Converter Systems
Frequency Translator Systems
Equalizer Products
Redundant Switchover Units
Uplink Power Control Units
Fiber Optic Links
SATCOM Amplifiers
SATCOM Frequency Synthesizers
SATCOM Custom Products
Space Products
Low-noise amplifiers
High-performance microwave mixers
Frequency synthesizers
Oscillators
Custom designed assemblies
Waveguide Products
Waveguide Amplifiers
Waveguide Components
Custom Solutions
News & Events
Support
Conversion Tool
RMA (Return Material Authorization)
Service and Repair Policies & Procedures
Warranty
Operation and Maintenance Manuals
AS9100/ISO9001 Certification
Customer Satisfaction Survey
Supplier Qualification Forms
Standard Terms and Conditions of Sale
Careers
Sales Channels
Contact Us
Search Results
1 to 50 of 84 Models Found
Pages: 1
2
Model
Quote
PDF
Freq
Min
(MHz)
Freq
Max
(MHz)
Gain
Min
(dB)
Gain
Flatness
(dB+/-)
Noise
Figure
(dB)
Noise
Temperature
(K)
Input
VSWR
Output
VSWR
P1dB
Out
(dBm)
IP3
Out
Typ
(dBm)
V1
Nom.
(V)
Curr1
Nom
(mA)
Outline
Drawing
AFS3-01000200-07-HE-6-SC-GRPC
Quote
MITEQ-AFS_HE.PDF
-
-
-
-
-
0
-
-
-
-
-
-
113384
AFSM1-01000200-09-8P-GW-SC-CSI
Quote
MITEQ-AFS_HE.PDF
-
-
-
-
-
0
-
-
-
-
-
-
113384
AFSM1-01000200-09-8P-GW-SC-SCR
Quote
MITEQ-AFS_HE.PDF
-
-
-
-
-
0
-
-
-
-
-
-
113384
AFS3-01000200-07-HE-6-SC-CSI
Quote
MITEQ-AFS_HE.PDF
-
-
-
-
-
0
-
-
-
-
-
-
113384
AU-1196-500
Quote
5
500
-5
0.5
-
0
2
2
-
-
15
23
176593
AU-1196-1000
Quote
5
1000
-5
0.75
-
0
2
2
-
-
15
23
176593
AFSM1-01000200-09-8P-GW-SC-GRPC
Quote
MITEQ-AFS_HE.PDF
-
-
-
-
-
0
-
-
-
-
-
-
113384
AFSM1-01000200-09-8P-GW-SC-GRPB
Quote
MITEQ-AFS_HE.PDF
-
-
-
-
-
0
-
-
-
-
-
-
113384
AFS3-01000200-07-HE-6-SC-SCR
Quote
MITEQ-AFS_HE.PDF
-
-
-
-
-
0
-
-
-
-
-
-
113384
AFS3-01000200-07-HE-6-SC-GRPB
Quote
MITEQ-AFS_HE.PDF
-
-
-
-
-
0
-
-
-
-
-
-
113384
AFS3-01150160-06-0P-FM-BTO
Quote
MITEQ-AFS_HE.PDF
1150
1600
38
0.2
0.6
43
1.5
1.5
0
-
5
75
113384
AFS3-01150160-06-FM-H
Quote
MITEQ-AFS_HE.PDF
1150
1600
38
0.2
0.6
43
1.5
1.5
0
-
5
50
113384
AFS3-01150160-06-0P-FM-BTO-Q
Quote
MITEQ-AFS_HE.PDF
1150
1600
38
0.2
0.6
43
1.5
1.5
0
-
5
75
113384
AFS3-01150160-06-0P-EM-BTO
Quote
MITEQ-AFS_HE.PDF
1150
1600
38
0.2
0.6
43
1.5
1.5
0
-
5
75
113384
AFS2-01700190-06-HE-6-5V
Quote
MITEQ-AFS_HE.PDF
1700
1900
27
0.75
0.6
43
2
2
0
10
5
25
113384
AFS3-01150160-06-FM-BTO-H
Quote
MITEQ-AFS_HE.PDF
1150
1600
38
0.2
0.6
43
1.5
1.5
0
-
5
75
113384
SAFS3-01000200-07-6-EM
Quote
MITEQ-AFS_HE.PDF
1000
2000
38
1
0.7
0
2
2
0
-
5
45
113384
AFS3-01150165-07-0P-6-HE-BTO
Quote
MITEQ-AFS_HE.PDF
1150
1650
38
1
0.7
0
1.5
1.5
0
-
4
40
113384
AFS3-01150165-07-0P-6-BTO-5V
Quote
MITEQ-AFS_HE.PDF
1150
1650
40
1
0.7
0
1.5
1.5
0
-
5
40
113384
AFS2-01000200-07-HE-6
Quote
MITEQ-AFS_HE.PDF
1000
2000
27
1
0.7
51
2
2
0
10
6
25
113384
AFS2-02600280-07-HE-4-5V
Quote
MITEQ-AFS_HE.PDF
2600
2800
22
0.75
0.7
51
2
2
0
10
6
25
113384
SAFS3-01000200-07-6-FM
Quote
MITEQ-AFS_HE.PDF
1000
2000
38
1
0.7
0
2
2
0
-
5
45
113384
AFS3-01150165-07-0P-6-HE
Quote
MITEQ-AFS_HE.PDF
1150
1650
38
1
0.7
51
1.5
1.5
0
10
4
40
113384
AFS3-01000200-07-HE-6
Quote
MITEQ-AFS_HE.PDF
1000
2000
38
1
0.7
51
2
2
0
-
6
50
113384
AFS3-01000200-07-HE-6-SC
Quote
MITEQ-AFS_HE.PDF
1000
2000
38
1
0.7
51
2
2
0
10
5
40
113384
AFS3-01000200-07-HE-6-5V
Quote
MITEQ-AFS_HE.PDF
1000
2000
38
1
0.7
51
2
2
0
10
5
40
113384
AFS3-01000200-07-HE-6-5V-BTO
Quote
MITEQ-AFS_HE.PDF
1000
2000
38
1
0.7
51
2
2
0
10
5
40
113384
AFS3-02000400-08-HE-4-BTO
Quote
MITEQ-AFS_HE.PDF
2000
4000
34
1
0.8
0
2
2
0
10
6
40
113384
SAFS2-02900310-08-5P-EM
Quote
MITEQ-AFS_HE.PDF
2900
3100
20
0.5
0.8
59
1.5
1.5
5
-
5
50
188821
AFS2-02000400-08-HE-4
Quote
MITEQ-AFS_HE.PDF
2000
4000
22
1
0.8
59
2
2
0
10
6
25
113384
AFS3-02000400-08-HE-4
Quote
MITEQ-AFS_HE.PDF
2000
4000
34
1
0.8
59
2
2
0
10
6
40
113384
AFS3-02000400-08-HE-4-AM
Quote
MITEQ-AFS_HE.PDF
2000
4000
34
1
0.8
59
2
2
0
10
6
40
113384
AFS3-02000400-08-HE-4-5V
Quote
MITEQ-AFS_HE.PDF
2000
4000
34
1
0.8
59
2
2
0
10
5
40
113384
AFS3-02000400-08-HE-4-BTO-5V
Quote
MITEQ-AFS_HE.PDF
2000
4000
34
1
0.8
59
2
2
0
10
5
40
113384
AFS2-02000400-08-HE-4-AM
Quote
MITEQ-AFS_HE.PDF
2000
4000
22
1
0.8
59
2
2
0
10
6
25
113384
AFS3-04000800-10-HE-4
Quote
DATAHE0001.PDF
4000
8000
30
1
1
76
2
2
0
10
6
60
113384
AFS2-04000800-11-HE-2
Quote
MITEQ-AFS_HE.PDF
4000
8000
20
1
1.1
84
2
2
0
10
6
40
113384
LNAS-20-04000800-11-0P
Quote
MITEQ-AFS_HE.PDF
4000
8000
20
1
1.1
84
2
2
0
10
6
40
113384
AU-1055
Quote
1
300
32
0.5
1.2
93
2
2
7
17
15
40
176592
AFS4-08001200-12-HE-4
Quote
H8-12_1.PDF
8000
12000
30
1
1.2
93
2
2
0
10
6
60
113384
AU-1189
Quote
1
100
33
0.5
1.2
93
2
2
7
17
15
40
176595
AFS3-08001200-14-HE-4
Quote
MITEQ-AFS_HE.PDF
8000
12000
20
1
1.4
111
2
2
0
10
6
50
113384
AMF-1F-08500960-15-5P
Quote
8500
9600
10
1
1.5
120
2
2
5
-
15
75
131580
AFD2-020040-15
Quote
MITEQ-AFD.PDF
2000
4000
24
1
1.5
120
2
2
5
15
15
30
AMF-3F-22002650-19-8P
Quote
22000
26500
22
1.5
1.9
160
2.3
2.3
8
-
15
125
128066
AU-1102
Quote
10
500
11
0.5
1.9
160
2.2
2.2
-4
6
15
18
176593
AU-1378
Quote
1
300
17
0.5
1.9
160
2
2
-
-
15
10
176592
AFS4-12001800-20-HE-4
Quote
MITEQ-AFS_HE.PDF
12000
18000
28
1.5
2
170
2
2
0
-
6
40
113384
AFS3-12001800-20-HE-4
Quote
MITEQ-AFS_HE.PDF
12000
18000
15
1.5
2
0
2
2
0
-
6
35
113384
AMF-1F-08500960-20-5P
Quote
8500
9600
10
1
2
170
2
2
5
-
15
75
131580
Pages: 1
2